Basic Info.
Model NO.
JYK-801D
Type of Body Fluid-Processing Device
Ingredients Blood Transfusion Device
Volume Alarm
8 Levels
Display
LCD
Transport Package
Carton
Specification
CE
Trademark
JYK
Origin
China
Production Capacity
50000/Month
Product Description
Medical equipment, volumetric infusion pump JYK-801D
The Features of Volumetric Infusion Pump
Complies with IEC 60601, high safety designation with dual CPUs.
High brightness LCD display and user-friendly operation interface.
Easy switch among d/min, mL/h and volume/time units.
Available for Bolus mode.
Anti-reverse function on motor to prevent upstream.
Self-check when start up and during infusion.
Top pressure sensor for preventing underflow.
Pressure and air-in-line detection devices both with 8 sensitivities setting, dynamically display pressure value.
IV set management function: Up to 20 IV sets can be added, stored and deleted in memory, convenient for operation after calibration.
Adjustable 8 volume levels of alarm for convenient operation in different environments.
CE certified.
The Features of Volumetric Infusion Pump
Complies with IEC 60601, high safety designation with dual CPUs.
High brightness LCD display and user-friendly operation interface.
Easy switch among d/min, mL/h and volume/time units.
Available for Bolus mode.
Anti-reverse function on motor to prevent upstream.
Self-check when start up and during infusion.
Top pressure sensor for preventing underflow.
Pressure and air-in-line detection devices both with 8 sensitivities setting, dynamically display pressure value.
IV set management function: Up to 20 IV sets can be added, stored and deleted in memory, convenient for operation after calibration.
Adjustable 8 volume levels of alarm for convenient operation in different environments.
CE certified.
Infusion Mode | Volumetric |
Pumping Mechanism | Peristaltic finger pump |
Optional Infuse Rate Unit | d/min, mL/h and volume/time |
IV Sets | Standard IV sets of 10, 15, 20 and 60d/mL, with diameter 3.4 ~ 4.5mm. |
FlowRate Range | 1.0 ~ 1200 mL/h |
Increment | From 0.1 mL/h to 99.9 mL/h, 0.1 mL increment; ≥100 mL/h, 1 mL increment. |
Flow Rate Accuracy | ≤ ± 5% (after calibration) |
Volume Limit | 1 ~ 9999 mL |
Volume Infused Display | 0 ~ 9999 mL & >9999 mL |
Purge Rate | 600 mL/h |
KVO Rate | 1 mL/h |
Bolus Mode | Available for Bolus mode,flow rate adjustable. |
Occlusion Pressure | Upstream and downstream pressure detection device with 8 sensitivities setting, 40 ~ 140KPa. |
Air-in-line Detection | Air bubble detected by ultrasonic and the device with 8 sensitivities setting,50 ~ 1000μL. |
Alarm Volume | 8levels setting |
Anti-reverse Function | Anti-reverse function on motor to prevent upstream |
IV Set Management and Flow Rate Calibration | IV sets can be added, stored and deleted in memory, convenient for operation after calibration. |
Self-check | Self-check when start up and during infusion |
Audio and Visual Alarms | Air-in-line, Door open, Upstream occlusion, Downstream occlusion, Infusion finished, No operation, Bottom empty, Battery low, Pump error, Motor reverse, AC power lost, etc. |
Display | Blue LCD with high brightness |
Power Source | AC: 100V ~ 240V, 50Hz/60Hz, ≤ 25VA |
Battery | Rechargeable Ni-MH battery: DC12V, 2000mAh, life: ≥ 4 hours at 25mL/h, remaining battery displayed. |
Operating Conditions | Temperature: 5°C ~ 40°C Relative humidity: 20% ~ 90% Atmospheric pressure: 70 ~ 106KPa |
Storage Conditions | Temperature: -20°C ~ 55°C Relative humidity: 10% ~ 90% Atmospheric pressure: 70 ~ 106KPa |
Classification | Class II, CF, IPX4 |
Dimensions and N.W. | 150mmx 150mm x 235mm; 2.3kg |
Application | Intravenous infusion for various liquid medicines, such as vascular expansion solution, anticancer drug, accelerative procreates drug, liquid nutrient, etc. Applicable for micro and rapid infusion. |