CE Mark Medical Volumetric Infusion Pump Jyk-801d

Customization: Available
Customized: Non-Customized
Certification: ISO13485

Products Details

Basic Info.

Model NO.
JYK-801D
Type of Body Fluid-Processing Device
Ingredients Blood Transfusion Device
Volume Alarm
8 Levels
Display
LCD
Transport Package
Carton
Specification
CE
Trademark
JYK
Origin
China
Production Capacity
50000/Month

Product Description

Medical equipment, volumetric infusion pump JYK-801D

The Features of Volumetric Infusion Pump

Complies with IEC 60601, high safety designation with dual CPUs.
High brightness LCD display and user-friendly operation interface.
Easy switch among d/min, mL/h and volume/time units.
Available for Bolus mode.
Anti-reverse function on motor to prevent upstream.
Self-check when start up and during infusion.
Top pressure sensor for preventing underflow.
Pressure and air-in-line detection devices both with 8 sensitivities setting, dynamically display pressure value.
IV set management function: Up to 20 IV sets can be added, stored and deleted in memory, convenient for operation after calibration.
Adjustable 8 volume levels of alarm for convenient operation in different environments.
CE certified.
Infusion Mode Volumetric
Pumping Mechanism Peristaltic finger pump
Optional Infuse Rate Unit d/min, mL/h and volume/time
IV Sets Standard IV sets of 10, 15, 20 and 60d/mL, with diameter 3.4 ~ 4.5mm.
FlowRate Range 1.0 ~ 1200 mL/h
Increment From 0.1 mL/h to 99.9 mL/h, 0.1 mL increment;
≥100 mL/h, 1 mL increment.
Flow Rate Accuracy ≤ ± 5% (after calibration)
Volume Limit 1 ~ 9999 mL
Volume Infused Display 0 ~ 9999 mL & >9999 mL
Purge Rate 600 mL/h
KVO Rate 1 mL/h
Bolus Mode Available for Bolus mode,flow rate adjustable.
Occlusion Pressure Upstream and downstream pressure detection device with 8 sensitivities setting, 40 ~ 140KPa.
Air-in-line Detection Air bubble detected by ultrasonic and the device with 8 sensitivities setting,50 ~ 1000μL.
Alarm Volume 8levels setting
Anti-reverse Function Anti-reverse function on motor to prevent upstream
IV Set Management and Flow Rate Calibration IV sets can be added, stored and deleted in memory, convenient for operation after calibration.
Self-check Self-check when start up and during infusion
Audio and Visual Alarms Air-in-line, Door open, Upstream occlusion, Downstream occlusion, Infusion finished, No operation, Bottom empty, Battery low, Pump error, Motor reverse, AC power lost, etc.
Display Blue LCD with high brightness
Power Source AC: 100V ~ 240V, 50Hz/60Hz, ≤ 25VA
Battery Rechargeable Ni-MH battery: DC12V, 2000mAh, life: ≥ 4 hours at 25mL/h, remaining battery displayed.
Operating Conditions Temperature: 5°C ~ 40°C
Relative humidity: 20% ~ 90%
Atmospheric pressure: 70 ~ 106KPa
Storage Conditions Temperature: -20°C ~ 55°C
Relative humidity: 10% ~ 90%
Atmospheric pressure: 70 ~ 106KPa
Classification Class II, CF, IPX4
Dimensions and N.W. 150mmx 150mm x 235mm; 2.3kg
Application Intravenous infusion for various liquid medicines, such as vascular expansion solution, anticancer drug, accelerative procreates drug, liquid nutrient, etc.
Applicable for micro and rapid infusion.
CE Mark Medical Volumetric Infusion Pump Jyk-801d
CE Mark Medical Volumetric Infusion Pump Jyk-801d
CE Mark Medical Volumetric Infusion Pump Jyk-801d
CE Mark Medical Volumetric Infusion Pump Jyk-801d
CE Mark Medical Volumetric Infusion Pump Jyk-801d
CE Mark Medical Volumetric Infusion Pump Jyk-801dCE Mark Medical Volumetric Infusion Pump Jyk-801dCE Mark Medical Volumetric Infusion Pump Jyk-801dCE Mark Medical Volumetric Infusion Pump Jyk-801dCE Mark Medical Volumetric Infusion Pump Jyk-801dCE Mark Medical Volumetric Infusion Pump Jyk-801d

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours