TG297 Industrial High Temp Spot Thermal Camera 160 x 120 Resolution/9Hz
- Experience the difference you can make with a true 160 × 120 IR pixel imager (19,200 pixels)
- High-temperature filter allows camera to measure and image temperatures up to 1030°C (1886°F)
- Work from a safe distance while scanning hightemperature objects thanks to the 30:1 spot ratio
- Identify the exact area that you're measuring using the bullseye laser pointer
- Diagnose problems faster with FLIR-patented MSX image enhancement
- Display and capture thermal or visual images with temperature readings
- Compare before-and-after stored images to demonstrate the problem and the repair
- View thermal images in your preferred color palette on the bright
Manufacturer Specs
General Specifications | |
Accuracy | ±1.5°C (2.7°F) for temperatures 50°C to 100°C (122°F to 212°F); up to ±3°C (±5.4°F) for -25°C to 50°C (-13°F to 122°F) and 100°C to 1030°C (212°F to 1886°F) |
Detector Type | Focal plane array (FPA), uncooled microbolometer |
Field of view (FOV) | 57° × 44° |
IR Resolution | 160 × 120 pixels |
Laser | Class 1 laser indicates the temperature measurement area; button-activated |
Object Temperature Range | -25°C to 1030°C (-13°F to 1886°F) |
Thermal Sensitivity/NETD | < 70 mK |
Warranty | FLIR 2-10 warranty |
Built-in Illuminator LED | 100 lumens, 6500 K flashlight |
FLIR Tools | Compatible |
COMPLIANCE & CERTIFICATIONS | |
Certifications | CE, CB, RCM, IEC60825-1, FDA, UL, CEC, NRCan |
CONNECTIONS & COMMUNICATIONS | |
Interface | USB 2.0, Bluetooth |
Storage Media | eMMC 4 GB |
USB | USB Type-C: data transfer/power |
USB - Standard | USB 2.0 High Speed |
ENVIRONMENTAL | |
Drop test | Designed for 2 m (6.6 ft) |
EMC | EN 61000-6-3 EN 61000-6-2 FCC 47 CFR Part 15 Class B |
Emissivity Correction | Yes: 4 preset levels with custom adjustment of 0.1-0.99 |
Encapsulation | IP 54 (IEC60529) |
Humidity (Operating and Storage) | 0-90% RH (0-37°C (32-98.6°F)), 0-65% RH (37-45°C (98.6-113°F)), 0-45% RH (45-55°C (113-131°F)) |
Operating Temperature Range | -10°C to 45°C (14°F to 113°F) |
Radio Spectrum | ETSI EN 300 328 FCC Part 15.249 RSS-247 Issue 2 EN 301 489-1:2011 EN 301 489-17:2009 |
Safety | CE/CB/EN61010/UL |
Shock | 25 g (IEC 60068-2-27) |
Storage Temperature Range | -30°C to 55°C (-22°F to 131°F) |
Tripod Mounting | 1/4 in.-20 on handle bottom |
Vibration | 2 g (IEC 60068-2-6) |
IMAGING & OPTICAL | |
Built-in Digital Camera | Yes |
Color palettes | Iron, Rainbow, White hot, Black hot, Arctic, Lava |
Detector Pitch | 12 µm |
Digital image enhancement | Yes |
Focus | Focus free |
Gallery | Yes |
Image Adjustment | Automatic |
Image Frequency | 8.7 Hz |
Image Modes | MSX® (Multi Spectral Dynamic Imaging) Visual with temperature reading |
Minimum Focus Distance | 0.3 m (0.98 ft) |
Minimum Measurement Distance | 0.26 m (0.85 ft) |
Spectral Range | 7.5 - 14 µm |
Digital Camera Resolution/FOV | 2 MP (1600 × 1200 pixels), 71° × 56° FOV |
MEASUREMENT & ANALYSIS | |
Center spot | Yes |
IR Temperature Resolution | 0.1°C (0.2°F) |
IR Thermometer Measurement Acquisition | Continuous scanning |
Languages | Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Russian, simplified Chinese, Spanish, Swedish, traditional Chinese, Turkish. |
Set-up Commands | Local adaptation of units, language, date, and time formats Screen brightness (high, medium, low) Gallery, deletion of images |
Spot Meter | Center spot on/off |
METER DATA | |
Camera size (L x W x H) | 210 × 64 × 81 mm (8.3 × 2.5 × 3.2 in) |
Camera weight incl battery | 0.394 kg (13.9 oz) |
Cover Glass Material | Optical grade silicon |
Display | 320 × 240 pixel, 2.4 in color LCD |
POWER | |
Battery operating time | 5 hours continuous scanning, 4.5 hours with laser on |
Battery Type | Rechargeable Li ion battery |
Battery voltage | 3.7 V |
Charging system | Battery is charged inside the camera |
Charging Temperature | 0°C to 45°C (32°F to 113°F) |
Charging Time | 4 hours to 90%, 6 hours to 100% |
Power Management | Adjustable: off, 5 min., 15 min., 30 min. |
Battery charge life | 30 days minimum |
SHIPPING INFORMATION | |
Includes | TG297, printed documentation, wrist strap lanyard, USB A to USB C cable, carry pouch |
STORAGE MEDIA | |
Image Storage Capacity | 4 GB for storage of up to 50,000 pictures |
Memory Type | Internal |
Saved image format | JPEG |
Tech Specs
Thermal Imagers/Building and Industrial Thermal Imagers Template | |
---|---|
Detector Size | 160 x 120 Sensor |
Thermal Sensitivity | 70 mK (NETD) |
Temperature Range Max | 1886 F |
Temperature Range Min | -13 F |
Image Frequency | 9 Hz |
Field of View | 57 x 44 Degrees |
Screen Size | 2.4 IN |
IR/Overlay Fusion Image | Yes |
Video Output | No |
Focus | Fixed |
Laser Spot | Yes |
Picture in Picture | No |
Video Recording | No |
Moveable Spots | No |
Touch Screen Display | No |
Minimum Focus Distance | 1 Ft (0.3048 M) |
Accuracy | -25 to 0°C (-13 to 32°F), acc. ±3°C (±7°F) 0 to 50°C (32 to 122°F), acc. ±2.5°C (±5°F) 50 to 100°C (122 to 212°F), acc. ±1.5°C (±3°F) 100 to 500°C (212 to 932°F), acc. ±2.5% 500 to 1030°C (932 to 1886°F), acc. ±3% |
Battery operating time Continuous | 5 HR |
Camera Light | Yes |
IR Digital Zoom | No |
Voice Annotation | No |
Intrinsically Safe | No |
Test Equipment General Attributes | |
Unique Features | • FLIR patented MSX enhancement adds sharp visual detail to thermal images, making it easier to diagnose problems. • Multipoint Laser pointer provides a circle to clearly show the area you are measuring. • Thermocouple Probe connector provides the use of General Purpose Type K Thermocouple Probe (to 260°C (500°F)) • Rugged and reliable with an IP54 enclosure that protects the camera from dirt, dust, and oil. • Six color palettes • Adjustable emissivity • Works with FLIR Tools • Stores images as Radiometric JPGs • 2MP Digital Camera |
Warranty | 1 YEARS |
Safety Approval | CE |
Interfaces I/O | USB |
Storage | Internal Memory |
IP Rating | IP54 |
Product Weight | 14 OUNCES (0.875 LBS) |
Product Height | 3.2 IN |
Product Length | 8.3 IN |
Product Width | 2.5 IN |
Data Logging | Yes |
HTS/Schedule B Number | 9027.50.4020 |
ECCN Number | 6A993.a |
Calibration Included | None |
Battery Type | Li-ion |
Power Supply Voltage | 120V/220V Universal, Battery Powered |
Country of Origin | Taiwan |
As an important international instrument sales platform, our company has the authorization qualifications of many international first-line brands. Relying on the advanced digital information management platform and international procurement platform, we provide more than 100,000 instruments, industrial MRO products, industrial products and spare parts to global customers. Our business scope: industrial testing, non-destructive testing, gas testing, electrical testing, laboratory testing, water quality testing, environmental testing, medical testing...