Basic Info.
Model NO.
HAC6601
Group
All People
Product Name
Hba1c Glycated Hemoglobin Analyzer
Testing Method
Chromatography/Ion Exchange Liquid
Testing Item
Glycated Hemoglobin Hba1c
Testing Scope
3% ~ 18%
Testing Time
4 Minutes (Including Reporting)
Sample Type
Venous Blood (EDTA Anticoagulation),PE
Sample Volume
5μl Whole Blood for Each Sample
Photometer
415nm LED Integral Flow Colorimeter
Testing Mode
Auto Test for Batch, Single Test for
Power Supply
AC220V/110V±22V 50/60Hz
Transport Package
Carton Packing
Specification
CE ISO
Trademark
Healicom
Origin
Jiangsu, China
Production Capacity
1000
Product Description
Hba1c Glycated Hemoglobin Analyzer
4 NEW COMPREHENSIVE UPGRADES
--- Faster! More Accurate! More Convenient!
- Inside heating - no pre-heating step outside, operate easily
- Durable pump tubing - Maintenance free micro pump, accurate sample volume, accurate results, imported high performance pump tubing, using life is for 1000 tests. Reduce replacement frequency, easier operation.
- Filter for avoiding blockage - With filter device for sample, avoid blockage, reduce failure rate greatly.
- Pressure monitor - With pressure testing device, monitor pressure at all times, results are more credible.
* Accurate Principle of Methodology
Adopts classical and accurate principle of methodology - Ion exchange liquid chromatography, It is the gold standard of HbA1C analysis, and it is the only analysis method to really separate HbA1C directly by measuring the piecemeal absorbance through continuous test on line, and obtain the correct area percentage with integration.
* Accurate separation 4-gradient elution
The novel 4-gradient elution for HbA1C can separate accurately glycated hemoglobin with 4-gradient elution of corresponding concentration reagent aiming at HbA1C instead of routine elution process produced by high and low concentration mixture.
* High Separation Liquid Chromatographic Column
High separation liquid chromatographic column made of imported resin with volume of Φ 9mm x 45mm and weight of 2.5g which is 15 - 20 times greater than general micro chromatographic column. High efficiency chromatographic column for 300 tests ensure the accuracy of test results.
* High Sensitivity 415nm LED Integral Photometer
High sensitivity 415nm LED integral photometer has the characteristics of correct wavelength, stable light source, full aluminum alloy structure, high anti-interference performance, multi-lens focusing, micro cuvettes and high sensitivity. It can record accurately analysis curve.
* Supply with Original Calibrator
The international standard value tracing is adopted. The authoritative reference material for quality control is used to transfer the numeric value. Each set of reagent is supplied with two sets of calibrator for proper calibration so as to ensure that the test results are correct and reliable and thoroughly to avoid individual error caused by factor calibration.
* Precision Chromatographic Column and Thermostatic Apparatus
Precision chromatographic column and reagent thermostatic control apparatus ensure that Chromatographic column and reagent are not affected by environment temperature and effectively guarantees the repeatability and correctness of the test results.
6 ITEMS OF HUMAN ORIENTED DESIGN, CONVENIENCE, SPEED AND RELIABILITY
* Real-time summarized chromatogram, Intelligence process detection
The advanced embedded micro processing system + intelligence control software can really display testing curve and the real redisplay of testing process and can monitor and alarm for test results, absorbency, signal potential, peak time and reagent consumption. It can be operated with high proficiency.
* Full-auto 25-position Sample Turntable, Optional Selection of Batch Test or Emergency Test
With full-auto 25-position sample turntable, it is unnecessary to use complicated rank sampling device and built-in hemolysis device. Batch test can be automatically carried out. Emergency test can be carried out at any time.
SPECIFICATIONS:
Basic Parameters | |
Testing Method | Chromatography/ion exchange liquid chromatography |
Testing Item | Glycated hemoglobin HbA1c |
Testing Scope | 3% ~ 18% |
Testing Parameters | Precision (CV) ≤3%, Accuracy (V) ≤1.50% |
Testing Time | 4 minutes (including reporting) |
Sample type | Venous blood (EDTA anticoagulation),Peripheral finger blood |
Sample volume | 5μl whole blood for each sample |
Functional Parameters | |
Photometer | 415nm LED Integral flow colorimeter |
Sampling mode | Full-auto 25-position sample turntable (20 sample positions, 2 quality control positions, 1 emergency position, 1 cleaning position, 1 zero position) |
Testing mode | Auto test for batch, single test for emergency |
Calibration | Optional selection of 2 points or 4 points calibration, optional selection of manual or automation, Equipped with1set of weight high and low level calibrators |
Thermostatic control | Column and reagent thermostatic control: 25 ± 0.5ºC |
Reagent matching | One piece of column and reagent consumable/300 pieces of testing samples |
Reagent allocation | Each standard package includes A, B, C, D eluent, calibrator, hemolytic agent, pump tubing |
Output Parameters | |
Display | 320x240 LCD Graphic Display, displaying real-time testing curve |
Printer | 58mm Thermal printer, printing testing curve and report |
Report Output | IFCC concentration value, NGSP area percentage, ADAG average glucose |
Data storage | 1000 test report (including testing curve) |
Communication interface | RS232 communication interface, connecting to HIS/LIS system |
Working Parameters | |
Power Supply | AC220V/110V±22V 50/60Hz 215VA |
Size | 408mm×390mm×230mm |
Weight | 9Kg |
Working Environment | Temperature 12ºC-30ºC,Relative humidity ≤85% |