Quickclean Hemostatic Powder for Gastro Surgery
Surgiclean® Absorbable Hemostatic Particles, honored as "Zhejiang High-Quality Manufactured Products" and "Zhejiang Excellent Industrial Products", is developed by Hangzhou Singclean after eight years of unremitting effort. It is prepared with potato starch as raw materials using reverse micro-emulsification technology and cross-linked modification to form a three-dimensional network structure.
A Wide Range of Applications:
•Cardiothoracic and cardiovascular Surgery
•Vascular Surgery
•Gynecological Surgery
•Urology Surgery
•Orthopedic Surgery
•General Surgery
•Plastic Surgery
•ENT Surgery
•Neurosurgery
•Cardiac Surgery
•Spine Surgery
•Endoscopic and laparoscopic Surgery
Applicator:
140mm; 380mm
Surgiclean® Absorbable Hemostatic Particles can successfully stop bleeding in 3 minutes and are enzymatically degraded by amylase and fully absorbed within 7 days.
Advantages:
1. Blood clot strength is 2-3 times as physiological blood clot.
2. Double hemostasis, mechanical plugging, accelerate endogenous clotting mechanism.
3. Safety-contains no animal or a human component, utilizing a purified plant source material is critical to minimizing the risks of infection and bleeding-related complications during surgery. The plant-based haemostat is currently the safest hemostatic agent.
4. Efficacy-dual action mechanism: ultra-hydrophilic nature enhances and accelerates the clotting cascade, coupled with the formation of a gelled matrix, which forms mechanical barrier to bleeding.
5. Ease of use-no prep or special storage requirements.
Characteristic
1). Stop bleeding quickly
2). Effectivly and reliably
3). No biological risk in vivo
4). Free from side effects
Absorbable hemostatic particles is indicated in surgical procedures as an adjunctive hemostatic device to assist when control of capillary, venous, and arteriolar bleeding by pressure, ligature and other conventional procedures is ineffective or impractical. Especially for the large-area oozing of the blood, depth bleeding and the part bleeding and the part bleeding that surgery can't reach, reduction of postoperative adhension .
How it works?
Spraing the Absorbable hemostatic particles on the bleeding surface of a wound, with its granular molecules absorbing rapidly the moisture from the blood and gathering the visible components (such as platelets, red blood cells, albumin, thrombin and fibin, etc.) in the blood at the surface of paticles to form a gelationous mixture, Meanwhile, it speeds up the activation of endogrnous hemostatic factors, shortening the clotting process abd forming soild and reliable local blood clot, stopping bleeding within several seconds, without leaving any traces locally .
Comparation between absorbable Absorbable hemostatic particles and traditional hemostatic materials:
Ingredient | Action mechanism | Hemostatic effect | |
Absorbable hemostatic particles | Plant starch | Double hemostasis, | +++++ |
mechnical plugging, | |||
accelerate endogenous | |||
clotting mechanism | |||
Absorbable gauze | Oxidized regenerated | Promote concentr | +++ |
cellulose | Ating the platelet | ||
and promote blood | |||
coagulation factor to | |||
stop bleeding | |||
Collagen sponge | Animal collagen | padding | ++ |
Fibrin glue | Cow/man thrombin | Mechanical plugging | +++ |
And blood | |||
Coagulation factor | |||
XIII |
Degradation and absorb | Tissue reaction | Blood borne disease | Inflammatory stimulus | Postoperative drainage | |
Absorbable hemostatic particles | Enzymolysis 5-7 days | no | no | no | Reduce |
Absorbable gauze | Degrade 7-10 days | light | no | yes | Reduce |
Collagen sponge | Enzymolysis 28-42 days | Relatively | yes | light | Not |
Fibrin glue | Degrade 10-15 days | light | yes | light | Reduce |