Siemens or Agg5.721 Standard Extension Connector Plug Set Containing All Terminals for a Typical Lmv5 System

Customization: Available
Customized: Customized
Certification: RoHS, CB, CCC, CE

Products Details

  • Overview
  • Detailed Photos
  • Recommend Products
Overview

Basic Info.

Model NO.
AGG5.721
Display Type
LED
Name
Siemens or Agg5.721 Standard Extension Connector
Model
Agg5.721
Color
Gray and White
Usage
for a Typical Lmv5 System
Weight
3kg
Keyword
Standard Extension Connector
Delivery Time
Payment After About 2 Days
Shipping Term
DHL/UPS/FedEx/TNT
After Warranty Service
Video Technical Support
Transport Package
Carton
Specification
20X10X11 cm
Trademark
Siemens
Origin
Germany
HS Code
8302600000
Production Capacity
1000

Product Description

Siemens OR AGG5.721 Standard Extension Connector Plug Set Containing All Terminals For A Typical LMV5 System

 
 
 
Siemens or Agg5.721 Standard Extension Connector Plug Set Containing All Terminals for a Typical Lmv5 System
LMV5 System Builder
The LMV5 Linkageless Burner Management System is comprised of many components in addition to the LMV5 itself.Use the following pages to choose the components needed for your specific application. See pages 21-25 for an LMV5 system order sheet. For additional technical information about any of the products listed, refer to Appendix B.

 

Detailed Photos

Siemens or Agg5.721 Standard Extension Connector Plug Set Containing All Terminals for a Typical Lmv5 System
Wiring in compliance with EMC regulations
1.Use shielded cables for the bus connections between LMV5..., SQM4.../SQM9... and AZL5... in control panels also
 2.Every actuator used with the LMV5... must be connected to the same functional earth (FE) or the same earthing point, using a short cable or a
low-resistance housing connection like the LMV5...
 3.Make certain that there is proper electrical contact between the housing of the SQM4.../SQM9... and functional earth (use lock washers and galvanically conductive mounting plates)
4. Run mains and bus cables
separately in separate cable ducts while observing the greatest possible distance
5.Run cables from and to ignition equipment separately while observing the greatest possible distance to bus cables
6.Use the shortest distance for the high-voltage cable from the ignition equipment to the ignition electrodes
7.When using bipolar ignition equipment, the cables should be run close together to ensure that the area of emissions is as small as possible W

 

Ignition

1.The ignition is a further strong source of interference. For this reason, please observe the following recommendations:
Keep the cable loop/length in the high-voltage ignition circuit as short as possible.
3.Use a special EMC ignition cable.
Avoid capacitive and inductive coupling to other signal lines. Use separate wiring for the high-voltage ignition cable, making sure to maintain the greatest possible distance from other cables and the burner housing. Example: Use an electrically insulating cable duct or distance spacer (made from plastic, for example) - see also the Appendix "Example for wiring, earthing, and shielding the LMV5 system".
4.Use a double-pole ignition where possible (see drawings below).
5.When using a double-pole ignition, the cables
should run close together to ensure that the emissions range is as small as possible.
Siemens or Agg5.721 Standard Extension Connector Plug Set Containing All Terminals for a Typical Lmv5 System

Siemens or Agg5.721 Standard Extension Connector Plug Set Containing All Terminals for a Typical Lmv5 System


PRODUCT SPECIFICATIONS
item
value
Condition
New
Warranty
1.5 years
Applicable Industries
Hotels, Garment Shops, Building Material Shops, Manufacturing Plant, Machinery Repair Shops, Food & Beverage Factory, Farms, Restaurant, Home Use, Retail, Food Shop, Printing Shops, Construction works , Energy & Mining, Food & Beverage Shops, Other, Advertising Company
2Weight (KG)
3
Showroom Location
None
Video outgoing-inspection
Provided
Machinery Test Report
Provided
Place of Origin
Germany
Brand Name
Siemens
Type
Gas Burner
Product name
Siemens OR AGG5.721 Standard Extension Connector Plug Set Containing All Terminals For A Typical LMV5 System
Model
AGG5.721
Brand
Siemens
After Warranty Service
Video Technical Support
Color
Grey And White
Shipping Term
DHL/UPS/Fedex/TNT
Application/Usage
Industrial Application
Delivery
payment after about 2 days
Siemens OR AGG5.721 Standard Extension Connector Plug Set Containing All Terminals For A Typical LMV5 System

Recommend Products

 

Siemens or Agg5.721 Standard Extension Connector Plug Set Containing All Terminals for a Typical Lmv5 System
Siemens or Agg5.721 Standard Extension Connector Plug Set Containing All Terminals for a Typical Lmv5 System
Siemens or Agg5.721 Standard Extension Connector Plug Set Containing All Terminals for a Typical Lmv5 System
Siemens or Agg5.721 Standard Extension Connector Plug Set Containing All Terminals for a Typical Lmv5 System
Siemens or Agg5.721 Standard Extension Connector Plug Set Containing All Terminals for a Typical Lmv5 System
Siemens or Agg5.721 Standard Extension Connector Plug Set Containing All Terminals for a Typical Lmv5 System

 

Siemens OR AGG5.721 Standard Extension Connector Plug Set Containing All Terminals For A Typical LMV5 System
Siemens or Agg5.721 Standard Extension Connector Plug Set Containing All Terminals for a Typical Lmv5 SystemSiemens or Agg5.721 Standard Extension Connector Plug Set Containing All Terminals for a Typical Lmv5 System

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours