Basic Info.

Model NO.
MIC600
Customized
Customized
Portable
Portable
Certification
FCC, CE, RoHS, Atex
Gas
Can Be Customized
Type
Thermal Conductivity Gas Analyzer
Alarm Type
Vibration+Sound+Light Alarm
Sensor
Imported Highly Precise Sensor
Sampling Method
Depending on Gas Nature
Accuracy
2% F.S Can Be Customized
Response Time
<30s
Certificate
ISO9001 Cnex CE Atex
Resolution
0.01ppm, 0.01%Lel, 0.01%Vol
Explosion-Proof Mark
Exia II CT6
Range
0 - 10/100/1000ppm/1%/25%
Protection Level
IP66
Diplay
HD LCD Display
Working Voltage
24V
Weight
1.8kg
Transport Package
Paper Carton
Specification
Highly Sensitive Imported Sensor
Trademark
Zetron
Origin
China
HS Code
9027100090

Packaging & Delivery

Package Size
15.00cm * 20.00cm * 15.00cm
Package Gross Weight
2.500kg

Product Description

 

MIC600 Online Fixed Composite Type Toxic and Harmful Gas Detector
 

Product Description

 

 

Zetron Mic600 Online Fixed Composite Type Toxic and Harmful Gas Detector
MIC600 series fixed gas detector is used for 24-hour continuous online monitoring and temperature and humidity measurement of various gas concentrations in the field, displaying the concentration and outputting standard signals on site, and remote data transmission. The 2.5-inch high-definition color screen displays the concentration in real time.

 

Detailed Photos

Zetron Mic600 Online Fixed Composite Type Toxic and Harmful Gas DetectorZetron Mic600 Online Fixed Composite Type Toxic and Harmful Gas DetectorZetron Mic600 Online Fixed Composite Type Toxic and Harmful Gas Detector

Product Parameters

 
MIC600 Specifications
Size 210×170×85mm   (L×H×W)
Weight 1.8 Kg
Response Time T90≤20 seconds
Allowable Error ±2% F.S
(higher precision levels can be customized)
Data Storage 100, 000 entries
Ingress Protection IP 66
Explosion-proof mark Exd2CT6, certificate number: CNEx15.1283
Detection Range Refer to Sensor Specifications (next page)
Power Supply The switching power supply of 24V, 2.1A is possible to drive 30 units of toxic gas detector, or 15 units of
flammable, infrared gas detector .
Working Environment Temperature: -40 ºC ~ + 70 ºC
Humidity: ≤10 ~ 95% RH (regular) non-condensing case
It should be customized in the case of use in the
condensing case, or the use environment should be specified at the time of ordering.
Range of working pressure: atmospheric pressure ± 30%, some sensors can detect under the pressure of 7 kg .
Alarms The default option is 1-way, and it is possible to select 3- way passive contact (dry contact) output, level III alarm,  and the alarm point can be set.
Field sound & light alarm (optional configuration).
Detection Principle Electrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, and so on, depending on the type of gas, range, field environment and user
demand.
Signal Output Bus system RS485 (RTU), three (four) wire system 4 ~
20mA, optional configuration: 0 ~ 20mA, 1 ~ 5V, 0 ~ 5V, 0 ~ 10V, wireless transmission, network transmission,
and SMS alarms.
Installation method Pipeline type, and wall mounting type. The working
pressure of the pipeline type is ± 30% of atmospheric pressure, and when exceeded this range, it is necessary for the depressurization treatment.


Connecting cable
Adopted 4 ~ 20mA three-core shielding cable, adopted four-core for RS485, when the distance exceeded 100   meters, the single wire diameter ≥1.5mm;
Both ends of the shielding layer will be connected to the ground, and good grounding should be ensured.
Standard Accessories Manual, qualification certificate, warranty card, outer packaging box
Zetron Mic600 Online Fixed Composite Type Toxic and Harmful Gas Detector
 
 

Application


Petroleum, chemical, pharmaceutical, environmental protection, gas distribution, flue gas analysis,air treatment and all other occasions that need to detect and analyze gas concentration.

Zetron Mic600 Online Fixed Composite Type Toxic and Harmful Gas DetectorZetron Mic600 Online Fixed Composite Type Toxic and Harmful Gas Detector

Certifications


Zetron Mic600 Online Fixed Composite Type Toxic and Harmful Gas Detector

Company Profile

Beijing Zetron Technology Co., Ltd, formerly Beijing Senre Technology Co., Ltd was founded in 2006, located in Beijing with convenient transportation access. We have almost 16 years experience in the retail, import and export of gas detection and monitoring equipment.

This experience has enabled us to form an organisation based on knowledge and expertise and have allowed us to supply a range of gas detectors and monitors that are tailored to our customers needs and budgets. Our aim is to provide the best values products with high quality and style.To provide the new affordable and complete service for gas detection needs for the industrial, engineering and shipping market and our friendly staff are here to help with advice and prices. So far, we have customers/buyers from over 20 countries/regions like Bulgaria, Brazil, Canada, China, Colombia, Germany, Iraq, Japan, Philippines, Russian Federation, Singapore, Taiwan, Thailand, Uruguay, United States, Ukraine, Vietnam, etc.

Zetron Mic600 Online Fixed Composite Type Toxic and Harmful Gas Detector

The list of countries still expanding.....!!
We are committed to become the International Well Know Provider to provide similar or better alternative, original merchandises & service to meet customers' needs, requirements and solutions.
 
Every customer is important to us and we strive to satisfy all our Customers needs and expectations.
Local and International Distributors, Dealers and Resellers are Welcomed! Please contact us at the homepage.
 

Applications


Zetron Mic600 Online Fixed Composite Type Toxic and Harmful Gas Detector
 

FAQ


Zetron Mic600 Online Fixed Composite Type Toxic and Harmful Gas Detector

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours